• SMP UI108 EAE S-KNX
    UNIVERSAL INTERFACE 8 INPUT

    General Specifications

    • Colored connection cables
    • Flush mounted into switch boxes
    • Does not require an external power supply
    • 8 input channels with each featuring following functions:
      • Switching
      • Dimming
      • Curtain control
      • Value and priority
      • Scene control
      • Pulse counter
  • General Specification

    EAE KNX Universal Dimmer Actuator has dimming functions which can be used by phase dimming only. The device can be operated manually via push button over enclosure. Each channel can be programmed via ETS5. UD106 has 6 independent channels and 3 channel grouping features. Channel features of dimming actuator;
    • Staircase lighting
    • Forced Operation
    • Channel Grouping (merging outputs for higher power loads)
    • Scene Function
    • Electrical Measurements (Voltage)
    • Error Detection (Load Error, Short-Circuit, Over-current, Over-voltage, Under-voltage, Over-heating )
    All features can be used separately or together. Please consider that those features will be processed depending on priority. Bus voltage fails and returns behavior can be set via ETS configuration.
  • SMP SA108 EAE S-KNX SWITCH ACTUATOR 8x16A C-LOAD

    General Specification

    8 independently configurable channels Manual control for each relay on the device using slide switches Does not require an external power supply Electric current control can be configured Following functions can be defined separately for each channel:
    • Stair function
    • External logic
    • Internal logic
    • Priority function
    • Threshold function
    • Transaction time
    • Sweep function

  • General Specification

    • 4 independently configurable channels
    • Manual control for each relay on the device using slide switches
    • Does not require an external power supply
    • Electric current control can be configured
    • Following functions can be defined separately for each channel:
      • Stair function
      • External logic
      • Internal logic
      • Priority function
      • Threshold function
      • Transaction time
      • Sweep function
  • SD110 1-10V Dim Actuator

    10 x 16A 1-10V Dim Actuator

    General Specification

    10 independent channels that can be parameterized via ETS4/ETS5 Manual operation feature for each channel using membrane switches Each channel can actualize any of these functions separately Following function list provided;
    • Staircase
    • Scene
    • Operating Hour
    • Forced Operation
    Configurable behaviour after voltage return, voltage failure or ETS download Integrated relay on each channel for complete switch off Does not require an additional power supply
  • RCU2000 Room Control Unit

    20x16A Outputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs. SMP RCU2000 EAE S-KNX
  • RCU1600 Room Control Unit

    16x16A Outputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.
  • General Specifications Input voltage range 150-275V AC, 50 60Hz Output 1: KNX bus power with an integrated choke. (30VDC, SELV) Output 2: Additional voltage output. (30VDC, SELV) Short-circuit and overload protected outputs LED indicators for Power, Overload and Reset status On device reset with Reset Button
  •  

    General Specifications

    Input voltage range 150-275V AC, 50 60Hz Output 1: KNX bus power with an integrated choke. (30VDC, SELV) Output 2: Additional voltage output. (30VDC, SELV) Short-circuit and overload protected outputs LED indicators for Power, Overload and Reset status On device reset with Reset Button
  • RCU0808 Room Control Unit

    8x16A Outputs + 8 Digital Inputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.
  • RCU0800 Room Control Unit

    8x16A Outputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.
  • EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.

    General Specifications

    Does not require an external power supply Room Control Unit covers all requirements of control in room applications and offers following functions:
    • Light switch
    • AC/DC blind control
    • Fan control
    • Fan Coil Control (2 & 3 point valve)
    • Dry contact inputs
    Switching resistive, capacitive and inductive loads in accordance with EN 60669 with following functions:
    • Staircase
    • External logic
    • Priority
    • Sweep
    18 independent input channels with following universal interface functions:
    • Switch / push button input
    • Dimmer control
    • Shutter/blinds control
    • Value transfer
    • Scene control
  • KNX Room Control Unit 16ch, 16 Input Fancoil, Switch, Blind actuator

    RCU1616 Room Control Unit

    16x16A Outputs + 16 Digital Inputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.
  • RCU1200 Room Control Unit

    12x16A Outputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.
  • RCU1212 Room Control Unit

    12x16A Outputs + 12 Digital Inputs


    EAE Room Controller Unit is an all-in-one KNX device to control various different room units from a single interface. Room Control Unit provides control of lights, blinds and fan coils as well as optional dry contact inputs.
  • General Specifications

    Fan Coil Actuator FCA100 covers HVAC systems of the electrical installation of room applications and offers following functions in one product.
    • Controlling fan coils (2 & 3-point valve)
    • Additional Heat or Cooling
    • Switching auxiliary load
    • Dry contact inputs
    • Temperature inputs
    FCA100 has 11 outputs, 6 inputs inside. These outputs and inputs are using for:
    • Auxiliary Output x1 (Relay 16A)
    • Fan Speed Output x3 (Relay 16A)
    • Fan Speed Output x1 (0-10 V Signal)
    • Valve Control Output x4 (Triac 0.5A)
    • Valve Control Output x2 (0-10 V Signal)
    • Dry Contact Input x4
    • NTC Sensor Input x2
    Suitable for switching resistive, capacitive and inductive loads as well as fluorescent lamp loads according to EN 60 669.
    •  Any kind of load (up to 16A per channel)
    Manual control is possible for each channel through the built-in button panel. Device has 4 independent input channels. Input channel operates as well as universal interface with following functions,
    • Switch / push button sensor
    • Dew-point sensor
    • Window sensor
    Device has 2 temperature input channels separately. Temperature Inputs can be used with following functions,
    • Single
    • Weighted (Multi temp sensor)
    220V auxiliary power is not required.
  • General Specifications

    • Up to 64 DALI devices connectable to DALI Bus (Fluorescent-ECG, LED driver)
    • Used with EAE DALI Commissioning Tool for DALI operations (addressing, grouping etc.)
    • Individual load control and 16 lighting scenes
    • Monitoring Fault status of DALI devices using different KNX group objects
  • 16 DALI Group Control


    DA100 KNX-DALI Gateway operates between KNX and DALI bus. DALI power supply is integrated in the device. DA100 is compliant with IEC 62386 standard.

    General Specifications

    • Up to 64 DALI devices connectable to DALI Bus (electronic ballast, LED driver, ECK)
    • Used with EAE DALI Commissioning Tool for DALI operations (addressing, grouping etc.)
    • 16 DALI Groups and 64 different lighting scenes
    • Each DALI group configurable to function as constant light, corridor or sequence function
    • Functional and battery life tests for DALI compliant emergency lighting fixtures to be sent through KNX
    • Monitoring Fault status of DALI devices as different KNX group objects
Go to Top